Red revolution

Red revolution

M3 Melbourne is one of two data centres in the Victorian capital that are set to house Australia’s largest and most comprehensive cloud ecosystem. 

Constructed by Kapitol Group, M3 Melbourne, a 100,000m² data centre in West Footscray, and M2 Melbourne, a 16,000m² data centre in Tullamarine, will collectively deliver 210MW of critical IT infrastructure to enterprise and government in what has been described as “a climate of unprecedented digital innovation”.  

Multidisciplinary firm HDR oversaw the design process. 

“Designing high-performance, resilient and scalable infrastructure at speed is no easy feat,” says HDR project leader Sam Faigen. “Utilising a data-driven design methodology, we have succeeded in delivering two purpose-built facilities, using modular and adaptable solutions, that will accelerate industry growth.”  

Stage 1

With Stage 1 of the 150MW masterplan now complete, M3 operates as a colocation facility for retail, enterprise and hyperscale customers, fitted out with administrative offices, collaboration spaces and highly adaptable data halls.  

Strategically located close to major electricity substations, the campus is situated 10km from Melbourne’s CBD, and resides at the junction between large industrial developments and low-scale residential dwellings.  

Faigen says the building form has been knitted into the area’s semi-residential urban fabric, set 20m back into the site to respect the neighbours. 

“This setback zone features densely plated swales, trees and ‘pocket parks’,” Faigen says, “As well as a community café along the tree-lined perimeter that gently transitions the site context from residential to industrial and puts community well-being first.” 

NEXTDC

M3 Melbourne is fitted out with administrative offices, collaboration spaces and highly adaptable data halls.

Tier iv resilience

Engineered to Uptime Institute’s Tier IV resilient standards by Arup, M3 has achieved an excellent Built Environment Sustainability Scorecard (BESS) and an industry-leading target PUE of 1.29. Planning consultants Urbis and project managers Newbridge were also key across the design and construction process. 

Ecolibrium chatted with Arup Senior Mechanical Engineer Callum Rutherford about the approach to the project’s mech engineering.  

    Ecolibrium: What was the initial brief from the client?

    Callum Rutherford: The initial client brief from NEXTDC outlined key parameters for the project, emphasising flexibility, energy and water efficiency, scalability, cost-effectiveness, and sustainability.  

    This basis of design document remains dynamic and continuously evolves as NEXTDC iteratively refines it across multiple facilities, maintaining a commitment to ongoing updates and improvements.
    Sustainability and energy efficiency have been top priorities for NEXTDC, with a focus on achieving a NABERS Data Centre 5 star rating.  

    Sustainability features include water-side free cooling, airside free cooling, solar PV, and rainwater harvesting. 

    NEXTDC

    The client brief from NEXTDC emphasised flexibility, energy and water efficiency, scalability, cost‑effectiveness, and sustainability.

    Eco: Does M3’s scale make it one of Australia’ bigger data centres?  

    CR: The site infrastructure will be installed over several stages, with the final design capacity capable of delivering approximately 150MW of IT capacity. This represents a large data centre in Australia, and was NEXTDCs largest facility at the time of design. The facility has the flexibility for hyperscale and retail clients, which have varying IT requirements.  

    Eco: Does the design process start with bench-marking best practice? 

    CR: The process of designing mechanical and building services is highly intricate and begins with benchmarking best practices and comparing mechanical solutions. 

    A detailed assessment considers factors like total cost of ownership, peak and annual PUE, annual WUE, safety in design, resilience to external factors (water and power supply to site), plant replacement, flexibility and scalability of design. 

    Energy usage analysis is undertaken for various mechanical and electrical options. Concurrently, massing blocks are being introduced onto layouts to determine equipment locations and feasibility.
    Crucially, the process involves collaborative workshops with the client, architect and services disciplines. 

    Eco: Does reaching the Uptime Institute’s Tier IV resilient standards put extra requirements onto the design? 

    CR: Simply put, yes, this does put extra requirements on the design, particularly regarding redundancy of equipment, support of equipment, water/fuel storage requirements, documentation, labelling, etc. However, in saying this, NEXTDC and Arup have intelligently met these requirements with modular systems, ensuring effective scalability while minimising redundant capacity 

    Eco: What were the project challenges overcome?  

    CR: The project encountered challenges in its early stages, primarily related to optimising space for equipment whilst maximising IT load and maintaining flexibility for diverse tenant types. Acoustics also posed a significant challenge due to the facility’s location, requiring substantial attenuation to meet noise criteria for the mechanical systems. 

    NEXTDC

    Acoustics posed a significant challenge due to the facility’s location.

    Eco: How important was collaboration? 

    CR: Collaboration was integral to the projects success due to its scale and complexity. Close cooperation with architects and other team members was imperative.
    Arup was fortunate to be appointed for MEP services, civil engineering, acoustics, fire engineering, ESD (environmentalsustainable design), communications and dangerous goods, which facilitated seamless in-house collaboration.

    Eco: What was most satisfying about working on the project? 

    CR: The marathon coordination sessions emerged as a highlight of the project. These sessions allowed experts from different disciplines to work collaboratively, aligning their goals and strategies to create a concept design that addressed all facets of the data centre.
    The achievement of UTI certification was also a pivotal moment, underscoring the success of the project and the commitment to excellence in design and resilience.

    Ecolibrium June-July 2023

    This article appears in ecolibrium’s Spring 2023 issue

    Want to read more?

    AIRAH MEMBERS

    Click here to view our archive of issues and features.

    NON-MEMBERS

    Become an AIRAH member or subscribe to Ecolibrium.

    Ticking the box

    Ticking the box

    The Australian Refrigeration Council (ARC) has implemented a new automated licence renewal process designed to reduce the amount of time required to complete a licence renewal application.

    Cautionary tales

    Cautionary tales

    Clearscope Legal’s Raphael Brown looks at some recent projects where HVAC&R has been in the compliance spotlight.

    Big shoes to fill

    Big shoes to fill

    If you’ve been an avid reader of Ecolibrium over the past decade and a half, you’ll notice that, for the first time in 160-odd issues, there’s a new photo on this page. It’s with a mixture of excitement and nervousness that I take the reins from the inimitable Matt Dillon.

    The time is now

    The time is now

    AIRAH’s IAQ 2024 conference underscored the once-in-a-century opportunity to improve indoor air quality – and what we need to do to seize it.

    ACT professional registration 

    ACT professional registration 

    The ACT has opened applications for mechanical engineers under its Professional Engineers Registration Scheme.  The scheme, which opened in March 2024, is being phased in across different branches of engineering:  Phase 1, which started in March 2024, covered civil...

    Purpose and place

    Purpose and place

    AIRAH Victorian division president Rula Karali, M.AIRAH, shares her international HVAC&R journey.

    Fairair

    Advertisement